Last Updated on 14 10 月, 2025 by

In environmental monitoring, lab analysis, and semiconductor processes, gas sampling accuracy defines scientific truth. As pioneers in precision stainless manufacturing, we specialize in SUMMA canisters, vacuum chambers, and specialty valves—achieving atomic-level hermeticity, sub-micron surface finishes, and zero-adsorption interiors for ppb-grade gas integrity.
I. Critical Failure Thresholds
Risk | Technical Limit | Our Solution |
---|---|---|
Gas Adsorption | Ra >0.1μm | Medical-grade EP (Ra ≤0.05μm) |
Weld Permeation Leak | He leak >1×10⁻¹⁰ mbar·L/s | Pulsed laser + EB remelting |
HAZ Intergranular Corrosion | Welding temp >600°C | Cold Metal Transfer (CMT) technology |
Metal Ion Contamination | Fe²⁺ release >0.1μg/m³ | Hyper-passivation (Cr₂O₃ ≥15nm) |
II. Core Technologies: Redefining Performance
-
Precision Hemispherical Forming
-
Flow spinning: 0.5–3mm thin-wall (roundness ≤0.03mm @ Φ200mm)
-
Hydrobulging: Seamless spheres (wall uniformity >95%)
-
Mirror-finished molds: Cavity Ra ≤0.02μm
-
-
Aerospace Welding (Seam/Nozzle)
Process Sequence:
[Vacuum chamber] → [Pulsed laser weld] → [EB remelt] → [Argon backing]-
Near-zero spatter: Heat input <15J/mm, HAZ <50μm
-
Full penetration: Undercut-free, reinforcement <0.05mm
-
Grain refinement: Ferrite <3% (ASTM E562 verified)
-
-
Ultra-Clean Surface Treatment
Process Mechanism Result Electro-polishing (EP) Selective dissolution Ra 0.03–0.05μm Electro-passivation (EPP) Dense Cr₂O₃ formation Fe²⁺ <0.01μg/cm² scCO₂ cleaning Nanoscale residue removal TOF-SIMS compliant -
Molecular Leak Verification
-
He leak test: Sensitivity 10⁻¹² mbar·L/s (equivalent to 1 helium atom leakage in 30 years)
-
QMS residue analysis: C6-C30 hydrocarbons <5ng/cm²
-
Bake-out protocol: 250°C/48h, base vacuum <5×10⁻⁹ mbar
-
-
Material Science
-
316L VIM-VAR (S <0.001%)
-
Hastelloy C-276 (halogen resistance)
-
SiOx nano-coating (polar molecule barrier)
-
III. Mission-Critical Applications
-
SUMMA Canisters:
✓ EPA TO-14/15 compliant, VOC stability >30 days
✓ Hydrocarbon background <0.2ppbv (NIST-traceable) -
High-Purity Valves:
✓ Nozzle weld leak <1×10⁻¹¹ secs He
✓ 2,000-cycle seal force decay <5% -
Vacuum MS Chambers:
✓ Outgassing <5×10⁻¹² Torr·L/(s·cm²)
✓ Magnetic compatibility (μr<1.001)
IV. Trusted by Elite Labs
-
Nanoscale Defect Control:
✓ SEM weld cross-sectioning
✓ White-light interferometry -
Certifications:
✓ ISO 17025
✓ ASME BPE 2019
✓ SEMI F57 -
Digital Twin Manufacturing:
✓ Weld distortion simulation (<3% error)
✓ Gas adsorption MD modeling
V. Fully Traceable Workflow
-
Requirements Lock: Gas specs/pressure profile/retention time
-
Material Genomics: Corrosion simulation report
-
Precision Execution: Live process monitoring
-
Cleanroom Packaging: Class 10 nitrogen-purged sealing
-
Delivery Dossier:
-
Leak test/He report bundle
-
NIST-traceable certificate
-
Ultra-Pure Vessel Operation Guide
-
Integrity in Every Molecule.
When a single chloride ion skews VOC analysis or a 40nm weld crack invalidates decades of data, we safeguard scientific truth with nano-scale surfaces, pico-level seals, and molecular cleanliness.